Documentation sections

Operate

Seeded-fault runs

A seeded-fault run checks the whole approved test suite against a catalog of known faults. The application is broken with one fault at a time, the suite runs each time, and the result shows which faults the tests caught and which escaped. It answers a different question from Break-to-Verify: not “can this test catch a fault?” but “does the suite catch the faults that matter?”

Break-to-Verify and seeded-fault runs (Demonstrated)

Both checks break the application on purpose, at different levels:

Break-to-VerifySeeded-fault run
ScopeOne new testThe whole approved suite
WhenBefore the test is mergedOn demand, from the Control Tower
FaultA controlled break for that testEvery fault in the catalog, one at a time
ResultPassed, weak or failed for the testCaught or escaped for each fault

A test can pass Break-to-Verify and the suite can still miss an important rule, for example when no approved case covers it. Seeded-fault runs make such gaps visible. Neither check affects pass rates or other Control Tower measures; their runs are red on purpose. See Break-to-Verify.

Starting a run

A seeded-fault run is started manually from the Control Tower by the automation engineer or the system administrator. The person chooses the platforms (web, Android, iOS, Windows) and the platforms run one after another, because each step is a full suite run against a fresh build of the application.

The fault catalog belongs to the application’s test mode. Each entry names the fault, the business rule whose tests should catch it and, where possible, the decision table that tells the correct and the faulty result apart. The application needs a fault switch that is active only in the test environment and only for the test run. For a pilot, the catalog and the switch are agreed together with your team. The portal interface is in Turkish today; the screen names on this page are translations.

How each platform is checked

For each platform the run has three phases:

  1. Baseline: the full suite runs without any fault. If the environment, infrastructure or build fails, the platform’s remaining steps are invalid. Tests that are already red in the baseline do not make the platform invalid; they are excluded from the following steps and listed.
  2. One run per fault: the full suite runs with one seeded fault. The fault is caught only if a test that was green in the baseline now fails on an assertion. Failing on a locator, a timeout or an unclear error is not evidence. If no baseline-green test fails, the fault escaped.
  3. Closing run: the full suite runs again without faults. If a baseline-green test fails here, it cannot be shown that the faults were removed, and the platform’s caught and escaped results become invalid.

Reasons for invalid steps are shown as short categories. Raw tool errors and device addresses go only to the audit log.

How the result is reported

The main catch rate counts only tests that were generated from approved cases. Hand-written tests in the same suite are reported separately, so that the rate says something about the generated tests. If no generated test was green in the baseline on a platform, that platform’s rate is not measured rather than zero.

The Control Tower shows a rate only when, on every selected platform, at least half of the catalog produced a valid caught or escaped result. Otherwise the run is listed with its details but the measure stays not measured. Each escaped fault points to the business rule and, where available, the decision table it violates, which helps the test specialist decide whether a case is missing. See Triage and Control Tower for the Quality tab where the result appears.

The current label is on the Capabilities page.

Updated:

Start with one story.

In a 30-minute call we look at your stack and a few of your stories, and tell you honestly whether a pilot fits.